61850DOCTOR


61850DOCTOR is a set of powerful tools that allows you to manage your IEC 61850 system. Simulate IEDs using logics based on IEC 1131 with VIRTUAL IED. Monitor and control your IEC 61850 devices with IED EXPLORER. Analyze goose traffic with GOOSE RADAR. 61850DOCTOR is the most powerful tool to keep your IEC 61850 system healthy.

FEATURES

VIRTUAL IED


  • Advanced IED server simulator
  • Modify any data values manually
  • Basic simulation with a sequencer
  • GOOSE publishing and subscribing
  • External equipment simulator as measurements or breaker
  • Advanced simulation using logics based on IEC 1131
  • Device interface with display, LEDs and buttons that can be used in the logics

 

 

Load an IED with its SCL file

61850DOCTOR image 01

 

 

See the model in tree or graphical view

61850DOCTOR image 02

 

 

Access to the control blocks

 

61850DOCTOR image 03

 

 

Modify any attribute manually at the data object level

61850DOCTOR image 04

 

 

You can also add an attribute to the sequencer to force automatic changes

 

 

 

See the value evolution in the trending view
61850DOCTOR image 06

 

 

 

Use the GOOSE viewer to see any GOOSE on your network

61850DOCTOR image 07

 

 

You can subscribe to any GOOSE using an SCL file or the GOOSEs on the network
61850DOCTOR image 08

 

 

The subscribed GOOSEs can be used in the logics editor for any advanced algorithm
61850DOCTOR image 09

 

 

Use the IED display to visualize model data, or to modify values with the buttons.

61850DOCTOR image 10

 

The external equipment view allows to modify measurements and breakers externally

 

Your virtual IED will be synchronized with any SNTP server

 

 

 

You will know the services exchanged and the existing connections


IED EXPLORER


  • IEC 61850 client to monitor and control IEC 61850 devices
  • It works with or without SCL files
  • No need to discover the complete model to exchange data
  • Discover the IED and create a compatible SCL file
  • All control models supported
  • Access to setting groups, buffered and unbuffered reporting, logs and files

 

3 WAYS TO MONITOR DATA

Discover the IED level by level.
You can always discover the complete IED model and save it into a compatible SCL file.
Or load the complete IED configuration from a SCL file and avoid the discovering process.

 

  • Drag and drop the data that you want to monitor
  • You can also monitor a dataset and remove the FCDAs that are not interesting to you
Imagen14

 

You can read and modify settings, when the IED expose them through IEC 61850

 

Choose the control objects that you need to operate on. IED EXPLORER informs you about the control model

 

Execute commands with the parameters needed

 

Receive data using the reporting mechanism

 

 

ADVANCED FEATURES

Save and restore the testing environment.
Access to logs.
Access to files.

 

You can add user labels to identify the information with your naming convention

 

Save the testing environment and load it later when you need to repeat some tests

 

Access to logs

 

Access to files using MMS


GOOSE RADAR


  • Specialized GOOSE analyzer
  • Compares the network traffic with the SCL files provided
  • Detect deviations between the SCL files and the network
  • Find problems with big repetition times
  • Keep track of changes during commissioning
  • Compare last GOOSE information under maintenance

 

 

Discover the GOOSE messages on the network and their repetition cycle as the distance to the center

 

Load and SCL file and now the references of the data are displayed

Use the filters to find the GOOSE under test

You can see the sequence of GOOSEs with status change

Or just check the events on the data received in the GOOSEs

Export the results to XML files to keep track of events happened in the test session

And of course, detect any problem during the test


DOCUMENTATION

DATASHEET

VIRTUAL IED

IED EXPLORER

GOOSE RADAR


VIDEOS

VIRTUAL IED


VIRTUAL IED


IED EXPLORER


IED EXPLORER


GOOSE RADAR


GOOSE RADAR